Industrial data connectivity

Factory data.
Clear context.
Visible quality.

Solidbase Systems is building an industrial data connectivity platform to connect plant sources, prepare data for MES use and make data quality explicit.

Current protocol coverage: OPC UA · Modbus TCP · MQTT

Illustrative data · Simulated sequenceProcess temperature · Machine 01 · AI_014
Current value
184.6°C
Good

No exception to report.

Last sample
10:41:53
Freshness
2 s

Good: no exception to report

GoodUpdates arriving
StaleUpdates stopped
BadOutside configured range
DisconnectedConnection lost
The problem

A number can look right and still be unusable.

A reading can be in range but out of date. A connection can fail while the last value remains on screen. Without clear quality and freshness information, a plausible number can be mistaken for a usable one.

Untrustworthy data must look untrustworthy.

The platform

From plant signals to operational context.

Connecting a source is the starting point. Preparing its data for MES use also means making its identity, units, context and condition understandable.

Illustrative mechanismReady
Plant sources
  • PLCs
  • SCADA
  • Sensors

Current protocol coverage: OPC UA · Modbus TCP · MQTT

The platform
  • ConnectivityConnects plant sources.
  • Structured representationIdentity, units and context made explicit.
  • Explicit data conditionQuality and freshness visible with each value.
Intended consuming systems
  • MES
  • ERP
  • Analytics
Illustrative mechanism, not a product diagram or a list of native integrations. Each reading carries its identity, units, context and condition through the same stations.
Data quality

See the condition behind the value.

A value is easier to evaluate when its condition, last update and relevant explanation are visible together.

Process temperature

Machine 01 · AI_014
Stale
Last known value
185.0°C
No update since the last sample.
Last sample
10:42:18
Freshness
Age 2 m 40 s

Process temperature

Machine 01 · AI_014
Bad
Latest reading
238.6°C
Outside the configured range for this example.
Last sample
10:43:02
Freshness
Age 1 s

Process temperature

Machine 01 · AI_014
Disconnected
Last known value
185.0°C
Connection to the source is lost. The number shown is retained.
Last sample
10:42:18
Freshness
Age 5 m 12 s

Illustrative data: one measurement shown in three separately selected examples.

Expertise

Software engineering and MES domain knowledge, together.

Solidbase Systems brings together software, product design, QA and IoT experience with manufacturing execution expertise.

01Discipline

Software & product engineering

Development, interface design, testing and connectivity expertise focused on making industrial data understandable and usable.

02Discipline

MES domain expertise

Manufacturing execution knowledge that helps ground the platform in plant workflows and operational requirements.

Current stage

Early-stage. One active pilot.

The platform is being evaluated at a two-wheeler manufacturing plant.

Additional connector coverage will be considered as pilots demand it.